5 software level 2 accessibility, 1 operator tools, Software level 2 accessibility – JLG 4017PS Service Manual User Manual
Page 163: Operator tools

9-5
3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7
Electrical System
9.5
SOFTWARE LEVEL 2 ACCESSIBILITY
The following parameters can be altered in the 2nd level of access to the machine’s software.
Refer to Section 9.17.2, “Analyzer Software Version P4.5,” for detailed software information.
9.5.1
Operator Tools
Menu
Setting/
Submenu
Visible
Comment
Change
Anti-theft Code?
Enter Current
Code: 0000
Enter New
Code: 0000
Access Levels
1,2
Requires the existing code to be entered before a new
one
Perform
Hardware
Exchange?
Transfer From
Display->UGM
Transfer From
UGM->display
Transfer Status:
In Progress…
Transfer Status:
Cycle Power
Now
Transfer Failed:
Cycle Power
Now
Access Levels
1,2
Initiates Transfer Of Non-volatile Memory Settings
Between The Cabin Display And UGM; Displays
Progress And Final Status For The Technician
Confirm Machine
Service?
Service
Complete?
Yes: Enter,
No: ESC
Access Levels
1,2
Records that preventive maintenance has been
performed
Review
Service History?
Service History
1:0h 0m
Access Levels
1,2
Displays the engine operating hours for the past fifteen
service confirmations
Set Service
Interval:500h
N/A
Access Levels
1,2
Increment/decrement the engine operating hours before
the next service interval
Review LMI
Shutoff History
LMI History
1:0H 0M
Access Level
1; Machine
Setup’s
MARKET is
CE or
AUSTRALIA
Displays the engine operating hours for the past fifteen
LMI shutoff (cancel) incidents
Vehicle Speed
Units: Kph
KPH
MPH
Access Levels
1,2,3
Selects units for vehicle speed display; default to KPH
when Machine Setup’s MARKET is CE or AUSTRALIA;
default to MPH when MARKET is ANSI