9-101
3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7
Electrical System
1335
524000
4
8-0-0
High side to low side short circuit in the injector 7 (in firing order)
1336
524001
4
8-0-1
High side to low side short circuit in the injector 8 (in firing order)
1337
2797
4
Injector diagnostics; time out error of short circuit to ground
measurement cyl. Bank 0
1338
2798
4
Injector diagnostics; time out error of short circuit to ground
measurement cyl. Bank 1
1339
2798
4
Injector diagnostics; short circuit to ground monitoring Test in Cyl.
Bank 0
1340
2798
4
Injector diagnostics; short circuit to ground monitoring Test in Cyl.
Bank 1
1341
524035
12
5-5-5
Injector diagnostics; time out error in the SPI communication
1342
524036
12
Injector diagnostics Slave; time out error in the SPI communication
1343
524004
12
8-0-4
Too many recognized misfires in cylinder 7 (in firing order)
1344
524005
12
8-0-5
Too many recognized misfires in cylinder 8 (in firing order)
1345
524069
9
Time out Error of CAN-Receive-Frame MSMon_FidFCCTO;
Master-Slave CAN communication faulty
1357
524052
11
Error memory Slave reports FID MSMonFC2; Shut-Off Path test
error of fuel injection system
1368
524052
11
Error memory Slave reports FID MSMonFC3; time out of engine
state messages (ComMS_Sys1-7) from master ECU
1378
523919
2
6-9-4
Sensor air pump air pressure; plausibility error
1379
523920
2
7-1-6
Sensor exhaust gas back pressure burner; plausibility error
1380
3253
2
6-9-2
Sensor differential pressure (DPF); plausibility error
1381
164
2
8-3-9
Rail pressure safety function is not executed correctly
1389
523922
5
7-1-5
Burner Shut Off Valve; open load
1390
523922
12
7-1-5
Burner Shut Off Valve; powerstage over temperature
1392
523922
4
7-1-5
Burner Shut Off Valve; short circuit to ground
1395
523921
2
7-1-4
Sensor burner temperature; plausibility error
1398
1136
0
6-8-1
Physical range check high for ECU temperature
1399
1136
1
6-8-1
Physical range check low for ECU temperature
1400
1136
3
6-8-1
Sensor error ECU temperature; signal range check high