JLG 4017PS Service Manual User Manual
Page 250

Electrical System
9-92
3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7
930
523721
8
6-8-9
Urea supply module temperature; duty cycle in failure range
931
523721
8
6-8-9
Urea supply module temperature; duty cycle in invalid range
932
29
3
1-2-6
Hand throttle idle validation switch; short circuit to battery
933
91
8
2-2-2
Accelerator pedal duty cycle PWM signal; signal range check high
934
91
8
2-2-2
Acceleration pedal cycle duration PWM signal;
signal range check high
935
91
3
2-2-6
Sensor error accelerator pedal; signal range check high
936
29
3
2-2-6
Sensor error hand throttle; signal range check high
937
29
4
1-2-6
Hand throttle idle validation switch; short circuit to ground
938
91
8
2-2-2
Accelerator pedal duty cycle PWM signal; signal range check low
939
91
8
2-2-2
Acceleration pedal cycle duration PWM signal;
signal range check low
940
91
4
2-2-6
Sensor error accelerator pedal; signal range check low
941
29
4
2-2-6
Sensor error hand throttle sensor; signal range check low
942
523921
3
7-1-4
Sensor error burner temperature; signal range check high
943
3532
3
6-7-0
Sensor error urea tank level; signal range check high
944
523921
4
7-1-4
Sensor error burner temperature; signal range check low
945
3532
4
6-7-0
Sensor error urea tank level; signal range check low
946
1079
13
2-8-2
Sensor supply voltage monitor 1 error (ECU)
947
1080
13
2-8-2
Sensor supply voltage monitor 2 error (ECU)
948
523601
13
2-8-2
Sensor supply voltage monitor 3 error (ECU)
956
677
3
5-1-2
Starter relay high side; short circuit to battery
957
677
4
5-1-2
Starter relay high side; short circuit to ground
958
677
5
5-1-2
Starter relay; no load error
959
677
12
5-1-2
Starter relay; powerstage over temperature
960
677
3
5-1-2
Starter relay low side; short circuit to battery
961
677
4
5-1-2
Starter relay low side; short circuit to ground
963
523922
5
7-1-5
Burner shut off valve; open load
965
523922
3
7-1-5
Burner shut of valve; short circuit to battery
967
523922
4
7-1-5
Burner shut of valve; short circuit to ground