Electrical System
9-64
3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7
HYDRAULIC
QUICK CONNECT
SELECT – SHORT
TO BATTERY
33205
Continuously
Auxiliary Function-A is prevented
Auxiliary Function-B is prevented
UGM J3-14 Aux Return is disabled
Continuous Auxiliary Hydraulics is
prevented
Hydraulic Quick Connect is
prevented
Auxiliary Release is prevented
Machine Setup’s HYDRAULIC
QUICK CONNECT is YES; short to
battery is detected on UGM J1-23
Power cycled
HYDRAULIC
QUICK CONNECT
SELECT – SHORT
TO GROUND
33206
Continuously
Auxiliary Function-A is prevented
Auxiliary Function-B is prevented
UGM J3-14 Aux Return is disabled
Continuous Auxiliary Hydraulics is
prevented
Hydraulic Quick Connect is
prevented
Auxiliary Release is prevented
Machine Setup’s HYDRAULIC
QUICK CONNECT is YES; short to
battery is detected on UGM J1-23
Power cycled
HORN – OPEN
CIRCUIT
33207
5000mS
Horn digital output is prevented
Platform attached; open-circuit is
detected on UGM J2-2
Power cycled
HORN – SHORT
TO BATTERY
33208
5000mS
Horn digital output is prevented
Platform attached; short to battery
is detected on UGM J2-2
Power cycled
HORN – SHORT
TO GROUND
33209
5000mS
Horn digital output is prevented
Platform attached; short to ground
is detected on UGM J2-2
Power cycled
DUMP VALVE –
OPEN CIRCUIT
33213
Continuously
Dump Valve digital output is
prevented
Machine Setup’s PLATFORM
OPTION is ENABLED; Cabin
Mode; open-circuit is detected on
UGM J2-13
Machine Setup’s PLATFORM
OPTION is ENABLED; Platform
Mode; 1,000mS after Platform
startup sequence is complete;
open-circuit is detected on UGM
J2-13
Power cycled
DUMP VALVE –
SHORT TO
BATTERY
33214
Continuously
Hydraulic functions are prevented
Dump Valve digital output is
prevented
Machine Setup’s PLATFORM
OPTION is ENABLED; short to
battery is detected on UGM J2-13
Power cycled
DUMP VALVE –
SHORT TO
GROUND
33215
Continuously
Dump Valve digital output is
prevented
Machine Setup’s PLATFORM
OPTION is ENABLED; Cabin
Mode; short to ground is detected
on UGM J2-13
Machine Setup’s PLATFORM
OPTION is ENABLED; Platform
Mode; PLT J2-19 digital output is
energized; short to ground is
detected on UGM J2-13
Power cycled
AUXILIARY
FUNCTION
SELECT – OPEN
CIRCUIT
33216
5000mS
Continuous Auxiliary Hydraulics is
prevented
Hydraulic Quick Connect is
prevented
Auxiliary Release is prevented
Machine Setup’s AUXILIARY
FUNCTION SELECT is YES;
Cabin Mode is selected; open-
circuit is detected on UGM J2-1
Power cycled