Page 165

9-7
3706PS, 3707PS, 4014PS, 4017PS, 33.7, 37.6, 37.7
Electrical System
9.5.2
Personalities
Fan Reverse
Timer: 2sec
2sec To 10sec
Access Level
1, 2, or 3;
Hydraulic
Variable
Speed Fan or
Reversing Fan
configured
Sets the length of time that the fan will be reversed
(cycling or demand)
Fan Reverse
Interval: 20min
5min To 60min
Sets the interval between cycling fan reversals
Tyre Selection:
Access Level
1, 2, or 3
Selects the tyre fitted for proper vehicle speed calibration
(refer to Vehicle Speed Calculation)
Default Gear
Selection: 2
1, 2, 3, 4
Access Levels
1,2,3
Sets the default transmission gear at power-up
ECM Service
Tool Access?
ECM Tool
Access?
Yes: Enter,
No: ESC
Access Level 1
When YES, the UGM shall not transmit CANbus
messages. This will allow maximum bandwidth for Deutz
service tools during re-programming. Power cycle is
required to resume normal operation.
Function
Description
Default Value
Main Lift
Allows the owner to adjust the Max Lift Up and Max Lift Down
function speeds
1400 mA (up)
1600 mA (down)
Soft Lift
Allows the owner to adjust the derate value when the boom
enters the soft lift zone
40%(3706PS, 33.7 & 37.6)
45% (3707PS & 37.7)
35% (4014PS & 4017PS)
Telescope
Allows the owner to adjust the Max Tele In and Max Tele Out
function speeds
1300 mA
Fork Tilt
Allows the owner to adjust the Max Fork Tilt Up and Max Fork
Tilt Down function speeds
1150 mA
Platform Level
Allows the owner to adjust the Max Platform Level Up and Max
Platform Level Down function speeds
800 mA
Platform Rotate
Allows the owner to adjust the Max Platform Left and Max
Platform Right function speeds
1000 mA
Platform Lift
Allows the owner to adjust the Max Platform Lift Up and Max
Platform Lift Down function speeds
1020 mA (up)
960 mA (down)
Platform
Telescope
Allows the owner to adjust the Max Platform Tele In and Max
Platform Tele Out function speeds
1000 mA (in)
1080 mA (out)
Outriggers
Allows the owner to adjust the Max Outrigger Up and Max
Outrigger Down function speeds
1000 mA
Frame Level
Allows the owner to adjust the Max Frame Level Left and Max
Frame Level Right function speeds
1000 mA
Bucket Lift
Allows the owner to adjust the Max Bucket Up and Max Bucket
Down function speeds
1400 mA (up)
1600 mA (down)