Clear alarm – Black Box COMPACT T1 MT850A User Manual
Page 532

B-4
Compact T1 - Release 6.1
Diagnostices & Troubleshooting
Alarms
Display Alarms
Use the alarms command to display the active alarms. Each alarm is related to a
particular address and has a severity category (major, minor, critical, alert). The
report can be filtered by port address and/or severity.
Syntax:
alarms [slot|slot:port|slot:port:channel] [category]
[severity]
> alarms
Time Date Severity Description
07:35:45 01/04/2002 Major Test Major Alarm
07:35:21 01/04/2002 Minor Test Minor Alarm
07:34:57 01/04/2002 Critical Test Critical Alarm
07:30:39 01/04/2002 Major 1:1-OCUDP Out of Service
03:50:55 01/04/2002 Major 1:1-OCUDP Loss of Signal
00:00:20 01/01/2002 Major 4:1-CMG Ethernet Link Down
00:00:20 01/01/2002 Major 5:1-RTR Ethernet Link Down
00:00:05 01/01/2002 Major A:2-DS1 Loss Of Signal
00:00:05 01/01/2002 Major A:1-DS1 Loss Of Signal
Total=10
Category = bri|ds1|env|equipment|fxo|fxs|rtr|v35
Severity = alert|critical|info|major|minor
Clear Alarm
Once an alarm is identified then the process of clearing it can begin.
l
Silence Alarm, if necessary (Alarm Cut Off CLI command: aco)
l
Check Connection
l
Check Cable, replace if necessary
l
Check hardware and replace if necessary
l
Call Customer Service