Alarms, Alarms -30 – Black Box COMPACT T1 MT850A User Manual
Page 114

5-30
Compact T1 - Release 6.1
CLI Commands
alarms
alarms
Use the alarms command to display the active alarms. Each alarm is related to a particular
address and has a severity category (major, minor, critical, alert). The report can be filtered by
port address and/or severity.
Syntax:
alarms [slot|slot:port|slot:port:channel] [category]
[severity]
Example:
alarms
Time Date Severity Description
07:35:45 01/04/2002 Major Test Major Alarm
07:35:21 01/04/2002 Minor Test Minor Alarm
07:34:57 01/04/2002 Critical Test Critical Alarm
00:00:20 01/01/2002 Major 5:1-RTR Ethernet Link Down
00:00:05 01/01/2002 Major A:2-DS1 Loss Of Signal
Total=10
[slot|slot:port|slot:port:channel]
[category]
[severity]
slot
A for the controller card, or 1 - 6 for service cards.
port
Port number.
channel
Channel number
bri
All BRI facility alarms
ds1
All DS1 facility alarms
env
Environmental Alarms
equipment
Equipment alarms not related to a DS1 interface
fxo
All FX0 facility alarms
fxs
All FXS facility alarms
rtr
All Router facility alarms
v35
All V.35 facility alarms
alert
Alert alarms (threshold crossing)
critical
Critical alarms
info
Information alarms
major
Major alarms (service effecting)
minor
Minor alarms (non-service affecting)