6-2 Power and Power-Up Modes

User's Manual

Tecra 8100 User's Manual – 8100_UK.DOC – ENGLISH – Printed on 13/12/99 as IM8100UK

Power on

Power off (no operation)

AC adaptor

not

connected

Main battery

charge is above

low battery

trigger point

• Operates

• LED: Main battery off

DC IN

off

Main battery

charge is below

low battery

trigger point

• Operates

• Alarm sounds

*3

• LED: Main battery

flashes orange
DC IN

off

Main battery

charge

exhausted

Computer goes into

Resume mode and shuts

down

*4

No main battery

installed

• No operation

*5

• LED: Main battery off

DC IN

off

2nd battery

charge is above

low battery

trigger point

• Operates

• LED: 2nd battery off

DC IN

off

2nd battery

charge is below

low battery

trigger point

• Operates

• Alarm sounds

*3

• LED: 2nd battery

flashes orange
DC IN

off

2nd battery

charge are

exhausted

Computer goes into

Resume mode and shuts

down

*4

No 2nd battery

is installed

• No operation

*6

• LED: 2nd battery off

DC IN

off

2nd battery indicator refers to the Secondary battery indicator.

*

1

When the main battery is not charging

*

2

If a main battery and a secondary battery are installed, the alarm does

not sound until the charge in both batteries falls below the low battery

trigger point.
*

3

If a main battery and a secondary battery are installed, the computer

does not enter Resume mode until the charge in both batteries is

exhausted.
*

4

When no secondary battery is installed

*

5

When no main battery is installed

When batteries are charged, the main battery is charged first. When it is

fully charged, the secondary battery is charged.