Chapter 7

Specifying settings concerning the transmission results for IP relay
transmissions (mode 382)

Specify the length of time until the transmission results for an IP relay trans-
mission times out and the operation that is performed when a timeout oc-
curs.

Settings at time of purchase

Specifying the setting

During the production of this unit, the settings in the shaded cells were se-
lected.

Bit

7 6 5 4 3 2 1 0

Setting

0 1 0 0 0 0 0 0 (HEX: 40)

Bit

Description

Setting

Description

Page Refer-
ence

7

Specifies the opera-
tion that is performed
when the return of
transmission results
for an IP relay trans-
mission times out.

0

Transmission error

----------

1

Normal transmission

6, 5, 4, 3

Specifies the length of
time until transmission
results for an IP relay
transmission times
out.

*

0000

0 minutes

----------

0001

5 minutes

0010

10 minutes

0011

15 minutes

0100

20 minutes

0101

30 minutes

0110

40 minutes

0111

50 minutes

1000

1 hour

1001

2 hours

1010

3 hours

1011

4 hours

1100

5 hours

1101

6 hours

1110

7 hours

1111

8 hours

2, 1, 0

--------------------------

000

*Do not change these bits
when specifying setting for
this function.

----------