4 button error codes – Balboa Water Group Titan Bath Control User Manual
Page 56

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,
834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
56
7/14/14
code message
description
0
Reload Configuration Table (No Configuration Table)
The configuration table is not downloaded to panel yet
0
Reload Configuration Table (No Active Configuration) The selected configuration number does not exist in the Active
Table
1
Missing Blower IBC
Configuration requires a Blower device (IBC) that does not exist
2
Missing Secondary Box (PVC, VSC)
Configuration requires a secondary device that not exist
3
Missing Primary Box (PVC, VSC)
Configuration requires a primary device that not exist
4
Not Enough Valves
Configuration requires more valves than the boxes can support
5
Swap Boxes
Panel connected to wrong box
6
No Communication Primary
The panel is not receiving messages from the Primary box
(PVC, VSC)
7
No Communication IBC
The Panel is not receiving messages from the IBC
8
ROM checksum fail
The power-up ROM self-test has failed
9
Module type error
The module is unable to detect what type it is
10
No zero-cross interrupts
Module is powered but not receiving AC zero-cross signals
11
Secondary comm lost
The Primary is no longer receiving messages from the
Secondary
99
Invalid error ID
Unknown error
error code
meaning
E01
Error, NoCommunicationIBC
Message #: 1, 7
E02
Error, NoCommunicationPrimary
Message #: 3, 6
E03
Error, NoCommunicationSecondary
Message #: 2
E06
Error, BadPrimaryOrSecondaryBox
Message #: 8, 9, 10, 11 ( for Boxes)
E07
Error, BadIBC
Message #: 8, 9, 10, 11 ( for Blower)
4 Button Error Codes