42135F
Codes, Abbreviations, and Terms
usInG Bath Button code confIGuratIons
Once the type of equipment to be installed is determined, then it's all a matter of understanding the nomenclature used
and cross referencing that information to the configuration tables.
VSC
Variable Speed Control
PVC
Primary Valve Control
IBC
Integrated Blower Control
Primary
A VSC or PVC connected directly to the panel (Do not confuse a "Primary" Valve Control [PVC] with Primary Location.)
Secondary
A VSC or PVC controlled by the Primary over the IR link
Tertiary
A second VSC or PVC controlled by the Primary over the IR link
Code
Equipment, such as Pumps, Blower, Wfall, Control Box, etc. Often preceded by a "Location" as either P for
Primary, S for Secondary, or T for Tertiary. The prefix of the Code is associated with the Location. The suffix of
the Code is associated with Valves Used.
Location
Source of the signal used to operate equipment. The Location is most often Primary, Secondary, Tertiary, or Blower.
Valves Used Any valve output connector on t
he Primary Valve Control, numbered 1-5.
code
function
SystemTimer
Starts the session timer and enables other device buttons.
system tImer codes
The System Timer button is used to start the internal Session Timer and enable the other device buttons. The current
implementation requires water to be present on all attached water sensors. If the button is held down while the Session Timer
is running, the remaining time will increment in 5 minute intervals until the maximum session time is reached.
lIGht codes
These codes provide On/Off control of a light. Only one light code may be assigned to a panel configuration.
code
location
vsc
Pvc
IBc
PLight
Primary
X
X
SLight
Secondary
X
X
BLight
Blower
X