background image

to view and edit user Preferences, press

AND

for 5 seconds.

The

session timer Menu will display the current time-out. Release both buttons.

Each press changes the length of the Session Timer.

Press to show

time/temp display Settings.

Edit

t = Time, h = Water Temp., or th = both.

If no temperature sensor is present, this is fixed at

d.t (display timer).

Press again to show the Temperature Display Menu.

Toggle between

c = Celsius, or f = Fahrenheit.

Press again to show the

store menu.

Select

st y (yes) to Save and Exit your new settings, or

st n (no) to Exit without saving new settings.

Press again to confirm the

store menu choice.

User Preferences

User Preferences allow changes to

certain default settings in the control.

note:

Previously saved variables will display solid; new
choices will flash.
If the control is displaying User Preferences and no
button is pressed within 10 seconds, the panel exits
User Preferences without saving any new settings.

Purge Cycle

(Blower Installations Only)

• Once a Session has ended, “

end” (of session) appears on the display indicating that

the Purge End Use Timer is active and counting down

The purge cycle will

begin after 20 minutes.
a)

Pur is then displayed and will last for 1 minute during the purge cycle.

b) Once the Purge Cycle is finished, the system shuts down and the display is blank.
c) Turning on a pump or blower during the End Use Timer will stop the timer and
start a new session.

A Purge Cycle removes standing water

from the plumbing and dries the air

delivery system. This helps maintain a

sanitary plumbing system. The purge

cycle lasts for 1 minute.

When setting user Preferences

Adjusts the variables in each menu

Navigates from one menu to the next

• hot Water detection (only if a temperature sensor is installed)

Water that exceeds 111° F will display:

[temperature] - too - hot.

The panel goes to normal operation when hot water is no longer detected.

• no Water detection

If no pump water is detected, the display will flash

no - h2o when a button is pressed.

• system error detection

If an error occurs in the bath system,

err will display.

Additional codes will follow to assist with diagnostics.

• led display:

con: “Configuration Settings”*

t29: Time remaining in minutes

sP6: “Speed” (SP1 is lowest speed)

Pul: “Pulse” Mode

rol: “Rolling” (Blower cycles up and down in speed)

Pt3: “Pattern” of pulses (PT1 is lowest speed)

• *

note: This is one of dozens of configurations available.

Display & Messages

• Display shows water display,

pattern changes, speed of devices

used, warning and error messages.

• If all sensors are installed, the

water temperature will display

during a user session. The water

temperature and time remaining

will alternate on the display.

• how the information is displayed

can be adjusted in User

Preferences.