beautypg.com

Balboa Water Group Micro Jet Replacement Nozzle User Manual

Tools required

background image

Installation Instructions

Micro Jet Replacement Nozzle

Tools required:

Medium sized flathead screwdriver

Medium sized needle nose pliers

STEP 1 – Adjusting Scalloped Flange

Rotate scalloped adjusting flange counterclockwise (looking
into jet) until it stops.

STEP 2 – Removing Scalloped Flange

Remove scalloped adjusting flange from jet retaining
flange by pulling straight out of jet. If it does not easily
release from its snapped-in position, place the flathead
of a screwdriver between the jet flange and the scalloped
adjusting flange and carefully pry it loose.

STEP 3 – Breaking and Removing Old Jet

Nozzle

The old jet nozzle will be broken into pieces when
removing. To do this, grip old jet nozzle tightly with needle
nose pliers at points shown, and firmly pull nozzle toward
you. This nozzle will most likely come out in pieces so be
sure to remove all pieces from jet body. Also, be careful not
to damage threads of jet body.

99510500 B January 20, 2010

Page 1 of 2

IMPORTANT SAFETY INSTRUCTIONS

READ & FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

CAUTION

Threads can be damaged when removing old nozzle. If threads are damaged you may not be able to install
the new nozzle and the entire jet may have to be replaced. To avoid this hazard, follow nozzle removal
instructions closely and be sure all broken nozzle pieces are removed from the jet.