HAND HELD JET INSTRUCTIONS

for Hydro Jet / Micro Jet / Slimline™ Jet

Micro’ssage / Converta’ssage

1. Turn off circulation pump.
2. Remove the therapy option from any of the Converta’ssage or Micro’ssage Jets, or remove

the eyeball from the Hydro, Micro or Slimline™ Jet.

3. Remove the nozzle from inside the jet, by turning it counter-clockwise. (A 9/16” nut driver

or a 9/16” socket on a ratchet extension will allow easy removal of the nozzle from the

Hydro Air Jets.)

4. Install the Hand Held Jet Adapter (#1) by threading it into the opening from which the nozzle
was

removed.

NOTE: There are TWO DIFFERENT sets of threads on the adapter.

1. The first set screws into the Hydro, Micro & Slimline™ Jets. If you are installing the

Hand Held Jet (#3) into one of these jets, simply thread the adapter into the

orifice

threads.

2. The second set of threads fit the Converta’ssage® and Micro’ssage® Jets. If you need

to adapt your Hand Held Jet to one of these models, you must cut the first set of

threads off with a PVC cutter or a hacksaw. Remove any plastic burrs that remain.

5. The hole on the float (#2) must be above the water level to draw air.
6. Start the circulation pump.
7. Squeeze the trigger (#4) to start the Hand Held Jet (#3) and release the trigger

(#4) to stop it.

TO CHANGE THERAPY OPTION IN HAND HELD JET:

Insert cage and eyeball (#5) (or flowpath, #6) into Hand Held Jet (#3) by pressing firmly

to snap into place.

CONTACT YOUR RETAILER OR SPA MANUFACTURER FOR OTHER THERAPY OPTIONS.

#1 Hand Held Jet Adapter
#2 Float
#3 Hand Held Jet
#4 Trigger
#5 Cage & Eyeball
#6 Flowpath