beautypg.com

2 & 6 button error codes, Error codes – Balboa Water Group Titan Bath Control User Manual

Page 55

background image

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,

834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.

55

42135F

2 & 6 Button Error Codes

code

message

description

E12 [a] Reload Configuration Table (No Configuration Table) The Panel does not have a configuration table loaded

E04 [b] Missing Blower IBC

The Panel can not communicate with the Blower

E02 [b] Missing Secondary Box (PVC, VSC)

The Primary Box cannot communicate with the Secondary Box

E01 [b] Missing Primary Box (PVC, VSC)

The Panel can not communicate with the Primary Box

E05 [c] Primary Comm lost

The Primary Box has stopped communicating with the Panel

E08 [c] Blower Comm lost

The Blower has stopped communicating with the Panel

E11 [a] ROM checksum fail

Checksum error in the Panel program

E09 [a] Module type error

Module is incorrect type

E10 [a] No zero-cross interrupts

No zero-cross interrupt

E06 [c] Secondary Comm lost

The Secondary box has stopped communicating with the Primary

E07 [c] Expansion Comm lost

The Expansion box has stopped communicating with the Primary

E03 [b] Missing Expansion box

The Primary box cannot communicate with the Expansion box

message 1

message 2

message 3

message 4

Err

E12

no

CFG

Err

E04

no

IbC

Err

E02

no

Ut2

Err

E01

no

Ut1

Err

E05

Ut1

Cnn

Err

E08

IbC

Cnn

Err

E11

Ut

CSU

Err

E09

Ut

tYP

Err

E10

0

CrS

Err

E06

Ut2

Cnn

Err

E07

Ut3

Cnn

Err

E03

no

Ut3

codes, type of errors

[a] Internal, serious errors that should never occur
[b] Startup errors when a box cannot be located on the IR Link
[c] Runtime errors when a box stops communicating on the IR Link

Notes:

• Ut stands for Under Tub box.

• IbC stands for Integrated Blower Control -- our blower with the box electronics built in.
• Startup and Runtime errors are communication related and will occur if boxes required by the

configuration are missing or communications are lost while running.

Error Codes