2 & 6 button error codes, Error codes – Balboa Water Group Titan Bath Control User Manual
Page 55

Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,
834 b2, Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
55
42135F
2 & 6 Button Error Codes
code
message
description
E12 [a] Reload Configuration Table (No Configuration Table) The Panel does not have a configuration table loaded
E04 [b] Missing Blower IBC
The Panel can not communicate with the Blower
E02 [b] Missing Secondary Box (PVC, VSC)
The Primary Box cannot communicate with the Secondary Box
E01 [b] Missing Primary Box (PVC, VSC)
The Panel can not communicate with the Primary Box
E05 [c] Primary Comm lost
The Primary Box has stopped communicating with the Panel
E08 [c] Blower Comm lost
The Blower has stopped communicating with the Panel
E11 [a] ROM checksum fail
Checksum error in the Panel program
E09 [a] Module type error
Module is incorrect type
E10 [a] No zero-cross interrupts
No zero-cross interrupt
E06 [c] Secondary Comm lost
The Secondary box has stopped communicating with the Primary
E07 [c] Expansion Comm lost
The Expansion box has stopped communicating with the Primary
E03 [b] Missing Expansion box
The Primary box cannot communicate with the Expansion box
message 1
message 2
message 3
message 4
Err
E12
no
CFG
Err
E04
no
IbC
Err
E02
no
Ut2
Err
E01
no
Ut1
Err
E05
Ut1
Cnn
Err
E08
IbC
Cnn
Err
E11
Ut
CSU
Err
E09
Ut
tYP
Err
E10
0
CrS
Err
E06
Ut2
Cnn
Err
E07
Ut3
Cnn
Err
E03
no
Ut3
codes, type of errors
[a] Internal, serious errors that should never occur
[b] Startup errors when a box cannot be located on the IR Link
[c] Runtime errors when a box stops communicating on the IR Link
Notes:
• Ut stands for Under Tub box.
• IbC stands for Integrated Blower Control -- our blower with the box electronics built in.
• Startup and Runtime errors are communication related and will occur if boxes required by the
configuration are missing or communications are lost while running.
Error Codes