Balboa Water Group Quiet-Flo Air Switch PushButton Blower Control User Manual
Quiet-flo, Heated blower with on/off air button, Timers
Quiet-Flo
TM
Heated Blower with On/Off Air Button
Timers
When the system motor is activated, a 30 minute timer is
automatically started. Once the 30 minutes run-time has expired,
any equipment automatically turns off.
When the blower is turned off, it waits for 15 minutes and then
runs a two-minute purge cycle. A purge cycle is designed to
remove standing water from the air system, which helps maintain
a sanitary bath system.
Blower Operation
Air switch operation:
1st Press: High speed.
•
2nd Press: Med. speed.
•
3rd Press: Low speed.
•
4th Press: Wave Mode.
•
5th Press: Off.
•
In Wave Mode, the blower starts at high speed,
•
reduces to low speed, then rises to high speed.
Then the cycle resumes.
Optional Heated Quite-Flo Blower
Any time the blower turns on, the heater turns on with it.
•
Line Voltage
Air Button with Quiet-Flo Blower
Wiring Diagram
Air Switch Button
(13070-XX - basic style*)
8’ Water
Detect Cable
(99742)
(Optional)
Air Switch Quiet-Flo Blower
with 600W Heater
(8141-6220)
Specifications / Overview
120 VAC 60 Hz.
•
30 minute timer.
•
Purge cycle.
•
4 Modes of operation:
•
Speed 3: High speed.
Speed 2: Med. speed.
Speed 1: Low speed.
Wave Mode: Speed diminishes to low, then returns to
high (within 12 seconds).
Control board mounted in blower housing.
•
If the main power is interrupted while the timer is
•
running, the system will return to standby mode when
power is restored.
© 2010 Balboa Water Group 40943 D May 24, 2010