Head2 - features, Features – Allied Telesis AT-PBC18 User Manual
Page 79

PowerBlade PBC18 Installation Guide
79
Table 27 lists the connector types and maximum operating distances of
the AT-PB200 and AT-PB202/x Series Switches.
Features
The PowerBlade Switches have the following features:
❑ LEDs for unit and port status
❑ Half-duplex or full-duplex operation
❑ MDI/MDI-X button that eliminates the need for a crossover cable
❑ DIP switches for configuring the ports
❑ Data packet forwarding and filtering at full wire speed
❑ Store and forward switching mode
❑ Automatic address learning and aging
Table 27 AT-PB200 and AT-PB202/x Series Maximum Operating Distances
Model
10/100Base-TX Port
100Base-FX Port
Connector
Maximum
Distance
1
Connector
Maximum
Distance
2
AT-PB201
RJ-45
100 m (328 ft)
ST
2 km (1.2 mi)
AT-PB202
RJ-45
100 m (328 ft)
SC
2 km (1.2 mi)
AT-PB202/1
RJ-45
100 m (328 ft)
SC
15 km (9.3 mi)
AT-PB202/2
RJ-45
100 m (328 ft)
SC
40 km (24.8 mi)
AT-PB202/3
RJ-45
100 m (328 ft)
SC
70 km (43.4 mi)
AT-PB202/4
RJ-45
100 m (328 ft)
SC
100 km (62 mi)
AT-PB204
RJ-45
100 m (328 ft)
VF-45
2 km (1.2 mi)
AT-PB205
RJ-45
100 m (328 ft)
MT-RJ
2 km (1.2 mi)
AT-PB206
RJ-45
100 m (328 ft)
LC
2 km (1.2 mi)
AT-PB207
RJ-45
100 m (328 ft)
FJ
2 km (1.2 mi)
1. Maximum distance can only be obtained when the UTP/STP cabling is installed and verified to TIA/EIA 568A Commercial Building Telecommunications
Cabling Standard.
2. Maximum distance for 100 Mbps Optical Datalinks is dependent on the following factors: type of optical fiber, duplex mode of both end-nodes, and
maximum optical loss budget for each of the optical fiber at the operating optical wavelength.