Allied Telesis AT-PBC18 User Manual
Page 107

PowerBlade PBC18 Installation Guide
107
! 14
Operating Temperature: This product is designed for a maximum ambient temperature of 40° degrees
C.
! 15
All Countries: Install product in accordance with local and National Electrical Codes.
! 16
As a safety precaution, a 10 Amp circuit breaker should be installed at the supply end of the cable to be
used with this LAN equipment.
Always connect the wiring to the LAN equipment first before connecting the wiring to the breaker. To
avoid the danger of physical injury from electrical shock, do not work with HOT feeds. Always be sure that
the breaker is in the OFF position before connecting the wiring to the breaker.
! 17
Warning: Do not strip more than the recommended amount of wire. Stripping more than the
recommended amount can create a safety hazard by leaving exposed wire on the terminal block after
installation.
! 18
When installing this equipment, always ensure that the frame ground connection is installed first and
disconnected last.
! 19
Caution: “Safety Hazard” Check to see if there are any exposed copper strands coming from the installed
wire. When this installation is done correctly there should be no exposed copper wire strands extending
from the terminal block. Any exposed wiring can conduct harmful levels of electricity to persons touching
the wires.
! 20
This system will work with Positive grounded or Negative Grounded DC systems.
! 21
Lithium Battery - Should only be changed by trained and qualified technician.
Caution: Danger of explosion if battery incorrectly replaced. Replace only with the same or equivalent
type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s
instructions.
(Attention: IL y a danger d’explosion s’ily y a remplacement incorrect de la batterie. Remplacer
uniquement avec une batterie du même type ou d’un type recommandé par le constructeur. Mettre au
rébut les batteries usagés conformement aux instructions du fabricant).
Normen: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.
! 1
Hochfrequenzstörung
EN55022 Klasse A, EN61000-3-2, EN61000-3-3
! 2
Warnung: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen hervorrufen. In diesem Fall
müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
! 3
Störsicherheit
EN55024
! 4
Elektrische Sicherheit
EN60950, UL1950, CSA 950
! 5
Laser
EN60825
Sicherheit
! 6
Warnung: Laserprodukt der Klasse 1.
! 7
Warnung: Nicht direkt in den Strahl blicken.