Configuring snmp parameters, Use the snmp/config command to configure snmp p, Enter a to create a trap destination table and – Allied Telesis FORMULA 8200 User Manual
Page 76: Enter q to quit and then y to save the informat, Configuring snmp parameters -30

Operating and Managing the FORMULA 8200 Switch
4-30
Configuring SNMP Parameters
You can configure the FORMULA 8200 to communicate with a
network management station via SNMP (SNMP v.1 only). To
configure the FORMULA 8200 as an SNMP managed networking
device, you can provide system description, system contact, system
location, and both read and write community strings.
To configure the FORMULA 8200 as an SNMP managed
device:
1. Use the
SNMP/CONFIG
command to configure SNMP parameters
as in the following screen:
2. Enter
A
to create a trap destination table and then respond to the
prompts. For example:
— Enter
192.2.150.49
as the destination IP address.
— Press Enter to accept 162 as the default UDP port number.
— Enter
public
as the community string.
The screen displays the following similar information:
3. Enter
q
to quit and then
y
to save the information to flash as in the
following example:
/SNMP/CONFIG
SNMP Agent configuration:
system contact () : JOE ADMIN
system location () : ENGINEERING LAB
Read community string (public) :
Write community string (private) :
SNMP trap destination table is empty.
Enter A=add, C=change, D=delete, Q=quit
SNMP Trap Destination Table
Enter A=add, C=change, D=delete, Q=Quit:
Index
=====
IP Address
==========
UDP Port
==========
Community
==========
1.
192.2.150.49
162
public
Enter A=add, C=change, D=delete, Q=Quit:
q
OK to write SNMP config file (y/n)?
y