Videotec ULISSE PLUS User Manual
Page 51

EN - English - I
nstruc
tions manual
49
The monitor does not show the picture taken by the ULISSE,
but shows an image of the type:
INFO
------------------------
Device ID: 00001
Type : Rs485 only Rx
Baud Rate: 19200-8N1
Protocol : PELCO-D
Net Board: Fw05.01 Hw00
Mpp Board: Fw05.01 Hw00
Config. : 001
P.C. : UPT1SMSA005C
S.N. : 0000000000000
Upgrade : NET BOARD
Programming dip-switch ON.
Switch off the pan & tilt, switch down the firmware upgrade
dip-switch (number 1 in the baud rate section). Switch-on the
unit again.
Error E2:AUTOPAN CONFIGURATION.
The two presets used as limits have not been
programmed.
Program the two presets and then update the Autopan
configuration menu ("11.2 Saving the current position (Preset)",
page 44 and "9.6.6.7 Autopan Menu", page 33).
Error E3:WASHER DISABLED or
error E4:WASHER PRST DISABLED.
Washer system disabled.
Enable the washer system ("9.6.8.2 Washer Menu", page 36).
Error E1:PATROL CONFIGURATION.
The presets have not been programmed.
Program two or more presets and then update the Patrol
configuration menu ("11.2 Saving the current position (Preset)",
page 44 and "9.6.6.6 Patrol Menu", page 33).
Error PRESET XXX NOT ENABLED.
Recalling of a non programmed preset.
Save the preset using the relative control ("11.2 Saving the
current position (Preset)", page 44).
Tab. 16