beautypg.com

Videotec ULISSE PLUS User Manual

Page 51

background image

EN - English - I

nstruc

tions manual

49

The monitor does not show the picture taken by the ULISSE,
but shows an image of the type:

INFO

------------------------

Device ID: 00001

Type : Rs485 only Rx

Baud Rate: 19200-8N1

Protocol : PELCO-D

Net Board: Fw05.01 Hw00

Mpp Board: Fw05.01 Hw00

Config. : 001

P.C. : UPT1SMSA005C

S.N. : 0000000000000

Upgrade : NET BOARD

Programming dip-switch ON.
Switch off the pan & tilt, switch down the firmware upgrade
dip-switch (number 1 in the baud rate section). Switch-on the
unit again.

Error E2:AUTOPAN CONFIGURATION.

The two presets used as limits have not been
programmed.
Program the two presets and then update the Autopan
configuration menu ("11.2 Saving the current position (Preset)",
page 44
and "9.6.6.7 Autopan Menu", page 33).

Error E3:WASHER DISABLED or
error E4:WASHER PRST DISABLED.

Washer system disabled.
Enable the washer system ("9.6.8.2 Washer Menu", page 36).

Error E1:PATROL CONFIGURATION.

The presets have not been programmed.
Program two or more presets and then update the Patrol
configuration menu ("11.2 Saving the current position (Preset)",
page 44
and "9.6.6.6 Patrol Menu", page 33).

Error PRESET XXX NOT ENABLED.

Recalling of a non programmed preset.
Save the preset using the relative control ("11.2 Saving the
current position (Preset)", page 44
).

Tab. 16