1 telemetry line connections, 2 alarm contact and relay connections – Videotec ULISSE PLUS User Manual

Page 21

background image

EN - English - I

nstruc

tions manual

19

7.2.4.2 Alarm contact and relay connections

Signal

Vdc

O1 C1

O2 C2

+

V

Fig. 31

TERMINALS

DESCRIPTION

F1-F2

Additional lines

O1-C1 and
O2-C2

Clean output contacts, can be activated by
alarm or by user control

AL1, AL2, AL3,
AL4 and COM

Live controlled alarm inputs referring to
common COM

Tab. 07

GND

VIDEO

Signal

Fig. 28

7.2.4.1 Telemetry line connections

h

The installation is type TNV-1, do not
connect it to SELV circuits.

h

In order to reduce the risk of fire, only use
cable sizes greater than or equal to 26AWG.

The product is supplied with 2 RS485 serial
communication lines and 1 RS232 serial line. These
can be configured in various ways according to the
positions of dip-switches 10 and 9 on the Serial and
Address
selector ("7.4.5 Serial communication lines",
page 22
).

A1

B1

A2

B2

Signal

Fig. 29

TERMINALS

DESCRIPTION

A1-B1

Line RS485 (1)

A2-B2

Line RS485 (2)

Tab. 06

RS232

Fig. 30