--all-lg
Select all logical groups.
--all-ne
Select all network entities
--all-ug
Select all user groups
--lg=lg1,lg2,...
Specify the logical group(s) names or range.
--ne=ne1,ne2,...
Specify the network entity names or range.
--nodes=node1,node2,...
Specify the node(s) names or range.
--ug=ug1,ug2,...
Specify the user group(s) names or range.
EXAMPLES
To display all the sensors and alerts of the specified nodes:
# /opt/cmu/bin/cmu_monstat --nodes=n0001,n0002,n00[01-11]
To display all sensors values of all the nodes: (Alerts will not be displayed)
# /opt/cmu/bin/cmu_monstat --all-sensors --all-nodes
To display all alerts on all nodes part of 'sles11_x68_64' logical group:
# /opt/cmu/bin/cmu_monstat --all-alerts --prefix --lg=sles11_x86_64
To display cpuload and memory usage of the nodes n1,n2:
# /opt/cmu/bin/cmu_monstat --sensors=cpuload,memory_used --nodes=n[1-2]
To display cpuload sensor value and login alerts for node n1:
# /opt/cmu/bin/cmu_monstat --sensors=cpuload --alerts=login_alert
--nodes=n1
To display all sensors along with statistics like Min, Max, Mean, std deviation, etc:
# /opt/cmu/bin/cmu_monstat --all-nodes --all-sensors --stats
To show the sensors threshold status in colors:
# /opt/cmu/bin/cmu_monstat --all-nodes --color