HP Remote Assistant Card User Manual
Page 180

H LED Codes
162
UART Failure Codes
LED
Code
REPORT
codes
Failure Name
Failure Reason
Possible
Cause
2-2-1
2210
UART Register R/W Failure
Register cannot be
programmed correctly
2-2-2
2220
UART FIFO Failure
UART FIFO control
register not working
Defective
UART (U60)
2-2-3
2230
UART Data Loopback Failure
Couldn't successfully
loop back data
2231
UART Data Loopback Timeout
2-2-4
2240
UART Control Loopback
Failure
Couldn't successfully
loop back controls
A to D CONVERTER Failure Codes
LED
Code
REPORT
codes
Failure Name
Failure Reason
Possible
Cause
2-3-1
2310
+5 Volt Reading Above Limit
2311
+5 Volt Reading Below Limit
2-3-2
2320
+12 Volt Reading Above Limit
Reading obtained
outside of set limits
Defective AtoD
Converter (U84)
2321
+12 Volt Reading Below Limit
2-3-3
2331
-12 Volt Reading Above Limit
2332
-12 Volt Reading Below Limit
2-3-4
2340
Internal Temperature Reading
Above Limit
Reading obtained
outside of set limits
Defective AtoD
Converter (U84)
2341
Internal Temperature Reading
Below Limit
Defective temp
sensor (U85)
2-3-5
2350
ADC Timeout
AtoD didn't finish
conversion within
timeout period
Defective AtoD
Converter (U84)