Result code summary – HP Remote Assistant Card User Manual
Page 158

C Modem Commands
140
S-Register
Unit
Range
Default
Description
S11
1 mSec
80-255
80
Sets time duration of and spacing between
tones in tone-dialing.
S13
ASCII
0-127
37
Defines Remote Configuration Escape
Character.
S17
10 mSec
0-2.5
250 mSec
Defines length of break time (space) to PC.
S24
50 mSec
0-255
20
Sets DSR/CTS/CD dropout time. Default
(20) equals one second.
S25
100 mSec
0-255
0
Sets DTR dropout time.
0 default equals 50 mSec.
S30
min
0-255
0
Inactivity timer used to disconnect modem.
S32
100mSec
0-255
20
Sets time that modem will wait for a
sequence execution.
S34
ASCII
0-60
10
Buffer size for number of characters in AT
command string after on-line escape
sequence, before buffer is cleared and
escape sequence aborted.
Result Code Summary
Digit
(Terse)
Words (Verbose)
Effect
0
OK
Command was executed without error; ready for next
command.
1
CONNECT
Modem has detected carrier and gone on-line.
2
RING
Modem has detected ring caused by incoming call.
3
NO CARRIER
No carrier signal has been detected within allowed time.
4
ERROR
Error in Command line (too many, or invalid characters).
5
CONNECT 1200
Modem has detected carrier at 1200 bps and gone on-line.
6
NO DIAL TONE
No dial tone has been detected.
7
BUSY
A busy signal has been detected.
8
NO ANSWER
Remote system did not answer.
9
CONNECT 2400
Modem has detected carrier at 2400 bps and gone on-line.