beautypg.com

Actions, Switch-to-switch pic, Node responsive test – HP NonStop G-Series User Manual

Page 231: For the 6780 switch

background image

Current Speed

The speed of the port in bits per second.

Transceiver Device State

The initial state of the component at the time of discovery.

Values: OK, Fault

Transceiver Enabled State

Whether the transceiver is enabled.

Enabled: The component is operational.

Disabled: The component is present but not operational.

Fabric State

The state of the external ServerNet fabric from the local node to the
remote node connected via this port.

Up: At least one of the processors on the local node can
communicate with at least one processor on one of the remote
nodes.

Down: No processor on the local node can communicate with any
processor on any remote node.

Neighbor ServerNet Node

Node Number The ServerNet node number of the neighbor node.

Node Name

The name of the neighbor node.

Actions

Node Responsive Test

Tests the connectivity on the external ServerNet fabric from the local node to the remote node
connected via this port.

Switch-to-Switch PIC

A plug-in card (PIC) on the

6770 switch module

that connects to another switch on the same

fabric. The last part of the name contains the port number where the PIC is located. Only the
PICs in ports 8 through 11 of the switch are used for switch-to-switch connections.

Location in OSM tree: External ServerNet Fabric > Switch Group > Switch Module > Switch
> Switch PIC

Example: Switch PIC $ZZSMN.Y3.10 (indicates the PIC in port 10 of switch Y3)