Page 231: For the 6780 switch

Current Speed
The speed of the port in bits per second.
Transceiver Device State
The initial state of the component at the time of discovery.
Values: OK, Fault
Transceiver Enabled State
Whether the transceiver is enabled.
Enabled: The component is operational.
Disabled: The component is present but not operational.
Fabric State
The state of the external ServerNet fabric from the local node to the
remote node connected via this port.
Up: At least one of the processors on the local node can
communicate with at least one processor on one of the remote
nodes.
Down: No processor on the local node can communicate with any
processor on any remote node.
Neighbor ServerNet Node
Node Number The ServerNet node number of the neighbor node.
Node Name
The name of the neighbor node.
Actions
Node Responsive Test
Tests the connectivity on the external ServerNet fabric from the local node to the remote node
connected via this port.
Switch-to-Switch PIC
that connects to another switch on the same
fabric. The last part of the name contains the port number where the PIC is located. Only the
PICs in ports 8 through 11 of the switch are used for switch-to-switch connections.
Location in OSM tree: External ServerNet Fabric > Switch Group > Switch Module > Switch
> Switch PIC