Loads the controller operational code and starts the MIOE SAC. When the Start action finishes, the
MIOE SAC is in the Started state.

Stop

Rather than automatically stopping the MIOE SAC (as the Abort action does), this action first warns
you if the SAC is currently in use (and stops it only after you confirm).

Module

A set of components that share a common hardware interconnection, such as a backplane. Each
enclosure of a system contains one or more modules. For NonStop S7x00, S7x000, and S86000
servers, an enclosure contains one

group

, and a group contains only one module. The module is

considered a subcomponent of the group.

Example: Module 2.1

Attributes

Module

Service State

Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required.

Values

Temperature Sensor

Current Value The current temperature, in degrees Celsius (°C), inside the enclosure of the module.

Actions

Rediscover

Causes OSM to

refresh

and

reanalyze

all components within the module. Use this action in situations

such as:

OSM does not recognize a new CRU following a CRU replacement.

An alarm remains after the alarm condition has been fixed.

Redundant Power Scrub

Tests fault tolerance of the power environment within the module. If the results of the action indicate
a problem, check the Power State attribute of the individual CRUs to determine where the problem
lies.

This action is run automatically at 2:00 a.m. daily. It can also be performed manually at any time.