Normal Maximum Value

The maximum acceptable air intake temperature is 50 degrees Celsius. If
the temperature rises above 50 degrees, an alarm is generated.

Actions

None.

PMF (Processor Multifunction) CRU

Each processor multifunction (PMF) CRU in a NonStop server contains these components:

A processor and memory board (PMB), which contains a

processor

A

power supply

(S7000 only)

A

service processor (SP)

Three

SCSI controllers

And for PMFs in Group 1 only, an

MIOE

(Ethernet controller) to provide connectivity

between the service processor and the dedicated service LAN (for OSM).

Location in OSM Tree: System > Group > Module > PMF

Slot Location: PMF CRUs are located in slots 50 and 55 of a processor enclosure (service side).

Example: PMF (1.1.55)

Attributes

PMF

Service State

Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required.

Values

Physical

Power State

Whether the component is powered on.

Values

Part Number

The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.

Track ID

A unique serial number that identifies the component. Track IDs are used for
tracking components.

Hardware Revision

A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.

Logical