CRU. If initialization fails, an alarm is generated.

This action is triggered automatically when a new CRU is inserted while OSM is running or when an
(SCF) STATUS ADAPTER command is issued. If a CRU is inserted while OSM is not running,
perform this action after logging on to the OSM Service Connection.

Test Verify

Performs basic tests on the CRU. You can perform this action when the CRU is online.

LIF

The logical interface, associated with a physical interface (PIF), used by an ethernet controller port or
a ServerNet adapter port.

Location in OSM Tree:

For an Ethernet controller port LIF: System > Group > Module > PMF2 > MIOE > MIOE SAC >
MIOE PIF > LIF

For a ServerNet adapter port LIF: System > Group > Module > E4SA > E4SA SAC > E4SA PIF >
LIF

Example: LIF $ZZLAN.LANX

Attributes

LIF

Service State

Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required.

Values

Logical

LIF State

The state of the logical interface.

Values: Started, Stopped, Unavailable

Actions

Abort

Terminates operation of the LIF. When the Abort action finishes, the LIF is in the Stopped state.

Delete

Deletes the LIF.

Start