Iomf2 (i/o multifunction 2) cru, Attributes, Iomf2 – HP NonStop G-Series User Manual

Page 127: Iomf2 cru

background image

becomes primary

Disables the battery

Replace

Launches the Replace IOMF guided procedure, which provides step-by-step instructions for
replacing the IOMF CRU.

Storage ASIC Initialization Test

Prompts the storage subsystem manager process ($ZZSTO) to initialize the storage ASIC in the
CRU. If initialization fails, an alarm is generated.

This action is triggered automatically when a new CRU is inserted while OSM is running or when an
(SCF) STATUS ADAPTER command is issued. If a CRU is inserted while OSM is not running,
perform this action after logging on to the OSM Service Connection.

Test Verify

Performs basic tests on the CRU. You can perform this action when the CRU is online.

IOMF2 (I/O Multifunction 2) CRU

Each I/O multifunction 2 (IOMF2) CRU in a NonStop server contains these components:

A

service processor (SP)

Two internal

SCSI controllers

One external

SSAC

A ServerNet plug-in card (

PIC

), which provides connectivity to

internal ServerNet fabrics

Location in OSM Tree: System > Group > Module > IOMF2

Slot Location: IOMF2 CRUs are located in slots 50 and 55 of a processor enclosure (service side).

Example: IOMF2 (1.1.55)

Attributes

IOMF2

Service State

Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required.

Values

Physical

Power State

Whether the component is powered on.

Values