Gesa (gigabyte ethernet servernet adapter) cru, Attributes, Gesa – HP NonStop G-Series User Manual
Page 112: Gesa cru

Start
Starts the ServerNet/FX or ServerNet/FX 2 adapter field-replaceable unit (FRU) that is in the
Stopped state. During startup, the controller operational code is automatically loaded into the FRU.
When the Start action completes, the FRU is in the Started state.
Stop
Stops the ServerNet/FX or ServerNet/FX 2 adapter field-replaceable unit (FRU) that is in the Started
state. When the Stop action completes, the FRU is in the Stopped state.
Test Verify
Runs all the firmware diagnostic tests on the ServerNet/FX or ServerNet/FX 2 adapter
field-replaceable unit (FRU). This test takes about 10 minutes to complete. You must use the Stop
action to place the FRU in the Stopped state before you initiate the Test Verify action.
GESA (Gigabyte Ethernet ServerNet Adapter)
CRU
An adapter that connects the ServerNet connections inside a server to an Ethernet local area network
(LAN). The Gigabit Ethernet ServerNet adapter is similar to the Fast Ethernet ServerNet adapter but
offers enhanced performance.
The Gigabit Ethernet ServerNet Adapter (GESA) CRU contains one Gigabit Ethernet ServerNet
addressable controller (
), which contains one Ethernet physical interface (
Ethernet port on each GESA CRU.
Location in OSM Tree: System > Group > Module > GESA
Slot Location: GESA CRUs can be located in slots 53 and 54 in processor enclosures (service side)
or in slots 51, 52, 53, and 54 in I/O enclosures (service side).
Example: GESA $ZZLAN.GESA0 (1.1.53)
Attributes
GESA
Service State
Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required.
Physical
Power State
Whether the component is powered on.
Part Number
The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.