HP NonStop G-Series User Manual
Page 200
To update ServerNet II switch firmware:
In the tree pane of the OSM management window, expand the ServerNet Cluster resource
and navigate to the switch component of the switch module.
1.
Right-click the Switch component and select Attributes. In the Firmware section, check
the value of the Compare State attribute. If it is Down-rev, continue with this procedure.
2.
Right-click the Switch component and select Actions. The Actions dialog box appears.
3.
In the Available Actions drop-down list, select the Firmware Update action and then
click Perform action. Follow the screen prompts and monitor the status of the action.
4.
When the update is complete, right-click the Switch component and then select
Attributes. In the Firmware section, confirm that the value of the Compare State
attribute is Same.
5.
Updating ServerNet II Switch Configuration.
Note: You can change the configuration tag as part of the Update Configuration action.
However, you normally do this only when you are changing to a different network
topology for a ServerNet cluster. See
Updating ServerNet Cluster Topology
To update ServerNet II Switch configuration:
In the tree pane of the OSM management window, expand the ServerNet Cluster resource
and navigate to the Switch component of the Switch Module.
1.
Right-click the Switch component and select Attributes. In the Configuration section,
check the value of the Compare State attribute. If it is Down-rev, continue with this
procedure.
2.
Right-click the Switch component and select Actions The Actions dialog box appears.
3.
In the Available Actions drop-down list, select the Configuration Update action and
click Perform action. Follow the screen prompts and monitor the status of the action.
4.
When you are prompted to perform a Hard Reset action:
Click Yes to perform the reset now. ServerNet traffic through the switch is
temporarily disrupted.
●
Click No if you want to wait until later. The new configuration does not take effect
until you perform the Hard Reset action.
●
5.
When the reset is complete, right-click the Switch component and select Attributes. In
the Configuration section, confirm that the value of the Compare State attribute is Same.
6.