beautypg.com

Pmcu, Attributes – HP NonStop G-Series User Manual

Page 141

background image

Start

Starts the CRU's PIF. The PIF must be in the Stopped state before you perform this action. When the
Start action completes, the PIF is in the Started state.

Stop

Rather than automatically stopping the PIF (as the Abort action does), this action first warns you if
the PIF is currently in use (and stops it only after you confirm).

PMCU

The power monitor and control unit (PMCU) controls and monitors the battery connection to the DC
power distribution buses. Along with the service processor, the PMCU diagnoses the condition of the
batteries, fans, and power supplies and regulates the voltage supplied to the fans.

Location in OSM Tree: System > Group > Module > PMCU

Slot Location: PMCUs are located in slots 21 and 22 of processor enclosures (appearance side).

Example: PMCU (1.1.21)

Attributes

PMCU

Service State

Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required.

Values

Physical

Power State

Whether the component is powered on.

Values

Part Number

The part number of the component that was assigned in manufacturing. Use
part numbers for identifying and ordering parts.

Track ID

A unique serial number that identifies the component. Track IDs are used for
tracking components.

Hardware Revision

A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.

Temperature Sensor

Normal Minimum Value

The minimum acceptable air intake temperature is 5 degrees Celsius. If
the temperature falls below 5 degrees, an alarm is generated.

Current Value

The current temperature, in degrees Celsius (°C), inside the enclosure of
the module.