Actions – HP NonStop G-Series User Manual

Page 143

background image

Fan Voltage

The current voltage of the Fan CRU.

Main Rail Voltage

The voltage of the Main Rail, which supplies power to the CRU from its
own power supply

Disabled ServerNet Ports

This attribute indicates which, if any, ServerNet router ports on this CRU
are disabled. OSM actions to disable or enable a ServerNet port are
performed as directed by OSM alarm repair actions.

SCSI-Y Voltage

The voltage of the SCSI-Y path, the path configured for mirrored disks on
a system.

MOSFET Voltage

The voltage measured between the MOSFET switch and the diode to the
DCC. The MOSFET switch is located on the Other Rail between the
alternate power supply and the DCC.

Rail Minimum Voltage

The minimum voltage (39.6 volts) that must be available to power CRU.

SCSI-X Voltage

The voltage of the SCSI-X path, the primary path used for disks on a
system.

Rail Maximum Voltage

The maximum voltage limit (60 volts) for the CRU.

DCC Voltage

The operational voltage of the PMF2 CRU (specifically, the raw voltage
supplied to the DC-to-DC converters).

Other Rail Voltage

The voltage of the Other Rail, which connects the PMF/IOMF CRU to
the other power supply in the enclosure (to provide power in the event of
a problem with the Main Rail power supply).

Storage ASIC

Initialization State

The status of the storage ASIC in the CRU.

Values: Initialized, Uninitialized, Unknown

Actions

Disable ServerNet Port

Disables the specified ServerNet port on this CRU. Perform this action only as directed by OSM
alarm repair actions.

Parameter: Port Number

Enable ServerNet Port

Enables the specified ServerNet port on this CRU. Perform this action only as directed by OSM
alarm repair actions.

Parameter: Port Number

Force Power Off

Use this action to power off the CRU and all of its subcomponents only if the Prepare to Power Off
or Power Off actions fail. The Force Power Off does not perform the other precautionary checks that