Page 101: Fcsa fru

background image

Current Value

The current fan speed, measured in rotations per minute (RPM).

Alarms are generated if the speed of the fan falls below 1800 (minimum
RPM) or rises above 5800 (maximum RPM).

Normal Maximum Value

The maximum acceptable fan speed is 5800 RPM. If the speed rises
above 5800, an alarm is generated.

Actions

Enable/Disable

Restores or stops power to the fan. After servicing the fan or its associated PMCU, perform the
Enable action.

Parameter: Enabled (true = enabled, false = disabled)

FCSA

Fibre Channel ServerNet adapter. The FCSA object always displays two

FCSA FSAC

s, regardless of

whether they are both physically present. At least one must be present to perform FCSA firmware
updates. The FCSA FSAC attributes

Node Name

and

Port Name

indicate the presence of FCSA

FSACs and attached disks. Unlike many other adapters, the ports on the FCSA are numbered from
top down when viewing the FCSA installed in a rack. Thus, FCSA FSAC 1 is attached to the upper
port (port 1), FCSA FSAC 2 is attached to the lower port (port 2).

Note: If a ServerNet switch board is not present, FCSAs will not appear in OSM.

OSM will not display FCSA attribute information until an associated disk process is configured and
started. For more information, see the Fibre Channel ServerNet Adapter Installation and Support
Guide
.

Location in OSM Tree: System > Group > IOAM Enclosure > IOAM > FCSA

Example: FCSA (13.31)

Attributes

FCSA

Service State

Displayed in the Attributes tab and Attributes dialog box only if attention or service is
required.

Values

Physical

Hardware Revision

A code that identifies the generation of the component. Hardware revision
codes are used for tracking components.