Table 23 Warning Messages in Capacity Advisor (continued)

To correct

Probable cause

Message

(Options->Protocol Settings->Global
Protocol Settings).

process. You can also run vseassist
to troubleshoot connection errors.

happen when acimserver
process is not running on the
system.

Synchronize the managed node clock
to the CMS system clock.

Capacity Advisor cannot analyze
utilization across multiple systems

Sample time sample_time is not aligned
to hour intervals.

or servers when system clocks (and
therefore, data timestamps) are not
synchronized.

Set up the trusted certificate by
manually installing the system's

See message text.

system_name

: HP SIM requires trusted

certificates for managed systems but no
trusted certificate exists for this system.

certificate into the HP SIM Trusted
System Certificate List.

Install the WBEM utilization provider
on the system.

See message text.

system_name

: The Utilization WBEM

Provider is not installed.

On the managed system, execute the
command
/opt/wbem/sbin/cimserver

The WBEM provider on the system
is not running and should be
restarted.

system_name

: The WBEM server is not

running and should be restarted.

See message text.

See message text.

system_name

: Upgrade the Utilization

Provider on this system to version
A.01.06.00.00 or later.

If you prefer not to use the method
described in the message, change the

See message text.

The Name Resolution Service could not
resolve localhost on the CMS. To

value for the CMS_HOSTNAME property

correct this, make sure that either the

in the vseprefs.props file from

name localhost can be resolved on

localhost

to some other name that

resolves to the IP address of the CMS.

the CMS or change the
CMS_HOSTNAME setting in
/etc/opt/vse/vseprefs.props

to

a hostname for the CMS that can be
resolved. See the hosts(4) and
nsswitch.conf(4) manual pages.

See message text.

If HP SIM has not correctly
discovered all of the system

The system attribute "attribute-name"
is not available from HP SIM for the

attributes (operating system type,

workload-name

workload. Either run

model, CPU count/speed, and

"Identify" on the system in HP SIM and

memory size) some of the attributes

export the profile again, or correct these

needed to export the profile using

fields in the header of the exported profile
before importing it.

the capprofile command are
not available.

If the profile data originated from a
capprofile

export, re-export the data

When importing a file using
capprofile

, the input file header

The system attribute "attribute-name"
must be specified before this profile can
be imported.

after running Options

→Identify

must contain correct values for the

Systems...on the system in HP SIM, or

system from which the profile data

manually correct the values in the

was gathered. If one or more

header. See the capprofile(1M)

attributes have the value

command reference page for an
example of a correctly formatted file.

, the profile cannot be

imported.

Install the HP VM WBEM provider
(vmProvider) on the virtual machine or
correct the configuration problem.
For help with using vseassist, see
the HP Matrix Operating Environment
Getting Started Guide.

An HP virtual machine may be
discovered by HP SIM and labeled
as a standalone server if the
system does not have a properly
configured WBEM provider for HP
VMs. Such a system cannot be
collected from until it is discovered
by HP SIM correctly.

The system "system_name" has no
workload defined. Make sure to select
Tools

→VSE Management...in HP SIM

before running this command for the first
time. For HPVM Guests, please be sure
that the HPVM WBEM provider is properly
configured. If problems persist, run
vseassist

to further diagnose errors.

170

Capacity Advisor messages