Command warning messages – HP Matrix Operating Environment Software User Manual
Page 169

Command warning messages
Within the messages sections, messages appear in alphabetical order. Messages that start with
system_name
are placed at “s” in a list.
These messages alert you to specific conditions present in the user interface . Follow-up actions
may or may not be necessary.
For additional information, refer to
“Command reference” (page 133)
in this guide, as well as the
HP Systems Insight Manager Technical Reference Guide available at
Table 23 Warning Messages in Capacity Advisor
To correct
Probable cause
Message
Check for advisements and take
corrective action if desired.
Appears at the end of output if any
warnings were issued.
1 warning issued
or
n
warnings issued
Overlapping samples are automatically
ignored or invalidated in Capacity
Samples imported with
capprofile
that overlap in time
cannot be interpreted.
A series of overlapping samples begins
at time sample_time. The overlapping
samples starting at this time are ignored.
Advisor. Import the data again, taking
care to designate date ranges that do
not overlap.
The improperly formatted values will be
automatically marked as invalid, and
A sample line in the file imported
with capprofile contains values
that are improperly formatted.
Improperly formatted sample values at
time sample_time have been ignored.
will not be included in Capacity Advisor
reports.
Some formatting errors can be manually
corrected. See the capprofile(1M)
command reference page for format
examples.
Use a profile viewer to determine if the
sample contains a sufficient number of
valid data points to provide a
meaningful report.
See
“Out-of-memory errors in the Java
See
Java Heap Space. Please see the HP
Capacity Advisor User's Guide for more
information on this issue and possible
solutions.
The missing samples will be
automatically marked as invalid and
Samples imported with
capprofile
are missing for one
or more sample intervals.
Missing sample for 1 time interval at time
sample_time
.
or
will not be included in Capacity Advisor
reports. Use a profile viewer to
Missing samples for n time intervals at
time sample_time.
determine if the sample contains a
sufficient number of valid data points
to provide a meaningful report.
The negative samples will be
automatically marked as invalid and
A sample imported with
capprofile
contained a
Negative sample value at time
sample_time
has been ignored.
will not be included in Capacity Advisor
negative value for the value of a
metric.
reports. Use a profile viewer to
determine if the sample contains a
sufficient number of valid data points
to provide a meaningful report.
Ensure that the CMS has access to
WBEM. Run vseassist to
troubleshoot connection errors.
CMS access to WBEM, using
Bastille, ipf, or other means, has
been shut down.
No systems are available from HP SIM in
the “HPVSE” collection.
Add the required credentials to the
systems where you plan to run Capacity
Either no WBEM credentials have
been entered in HP SIM or HP SIM
No WBEM credentials are available for
system "system_name”. Please verify
Advisor, or run the cimserver
could not successfully use the
credentials entered. The latter can
that a valid WBEM account and password
for this system are configured in HP SIM
Command warning messages