FUTEK IPM600 (D610) Digital Display User Manual
Page 136
26.CONFORMITY TO EC DIRECTIVES
125
Attachment of ferrite core
It is necessary to attach a ferrite core to a sensor cable for a load cell or the like.
Attached ferrite cores
E04SR301334
For sensor cable
E04SR200935A
For power cable
F371
Load cell
Ferrite core
A cable is bound with a
lock.
CAUTION
- The F371 main body conforms to EMC directive EN61000-4-5
(lightning surge immunity) in combination with the lightning
surge protect.
- The F371 does not conform to EC directives with the CC-Link
option or Device Net option, and on a DC power source.