beautypg.com

Set reference junction temperature – GW Instek GDM-8200A User Manual User Manual

Page 39

background image

BASIC MEASUREMENT

39

Set reference junction temperature

Background

When a thermocouple is connected to the GDM-8200A
series, the temperature difference between the thermocouple

lead and the GDM-8200A series input terminal should be
taken into account and be cancelled; otherwise an erroneous

temperature might be added.

Type

Range

Resolution

SIM (simulated)

0 ~ +50°C

0.01°C

The terminal temperature is manually defined by the user.

Default value: 23.00

1. Open
reference
junction
menu

Press the Shift key, the TEMP
(Sensor) key, then the Down key.

The reference junction selection
menu appears on the display.

2. Edit
reference
temperature

Use the Left/Right key to move

the cursor, and use the Up/Down
key to change the value.
Default: 23.00

Press the Enter key to confirm the
value, or the Exit key to cancel.

The display goes back to the
default state.

(confirm)