40

Logging Interval

Specifies the interval of measurements logging in seconds. The range of the value is between 1 to 300.

 The accuracy of the logging interval is not guaranteed.

6.4

Log Display Section

When the logging is started, a log for each line is created in the log display section with the specified

interval.

6.5

Measurements Log File

When the [Save in a File] check box is selected in the [Logging Setting] dialog (

6.3.4), starting a

logging creates a measurements log file in the folder specified in [Location] and appends a log to the

log file.

The format of the measurements log file is described below.

File name

The file is created with the name of YYYYMMDD_HH_MM_SS.txt based on the time when the

logging is started.

File format

Text file delimited by comma. The first line includes the item names and the subsequent lines represent

measurements logs.

 Data in the log display section cannot be copied to the clip board or saved to a file. If you need to

keep the log in a file, select the [Save in a File] check box in the [Logging Setting] dialog

(

6.3.4) and use the measurements log file.

 Logging data displayed on a window or saved in a file is up to 3600 lines. If logging data exceeds

3600 lines, displayed data will be wrapped around and a new file will be created. Excess data will

be saved in the new file.

 Logging may stop if there is not enough empty space in the hard disc.
 Logging cannot be done during sequence execution.

CAUTION