beautypg.com

Memory, Store, Recall – GW Instek APS-1102 Control Software User Manual User Manual

Page 34: Reset, Figure 4-11 store and recall dialogs

background image

4 Basic Controller

21

4.4

Memory

This section explains the method to communicate with the APS power source and access or reset the

basic setting memory (internal memory).

Figure 4-11 Store and Recall Dialogs

4.4.1 Store

The Store dialog can be opened by any of the following two methods. In the Store dialog, specify the

internal memory number from the [Memory No.] list, and then click OK to execute the store processing

on the APS power source.

 From the Menu Bar, click [Memory] - [Store].
 On the Tool Bar, click the [Store] icon (

4.2.2).

4.4.2 Recall

The Recall dialog can be opened by any of the following two methods. In the Recall dialog, specify the

memory number from the [Memory No.] list, and then click OK to execute the recall processing on the

APS power source. After the APS power source finishes the recall processing, the software inquires the

APS power source, and updates each setting value in the windows of the software to the recalled value.

 From the Menu Bar, click [Memory] - [Recall].
 On the Tool Bar, click the [Recall] icon (

4.2.2).

 Performing the recall operation with the output on results in an error.

4.4.3 Reset

From the Menu Bar, click [Memory] - [Reset]. The connected APS power source is reset to the factory

defaults.

 Performing the reset operation with the output on results in an error.

CAUTION

CAUTION