System:communicate:enable, System:communicate:gpib[:self]:addr ess – GW Instek PSU-Series Programming User Manual User Manual
Page 91
REMOTE CONTROL
91
Parameter
HIGH | 0
Active high
LOW | 1
Active low
Return Parameter
Returns the logic setting.
:SYSTem:COMMunicate:ENABle
Set
Query
Description
Enables/Disables GPIB, USB or other remote
interfaces such as Sockets and the Web Server.
Syntax
Query Syntax
:SYSTem:COMMunicate:ENABle {
|OFF|ON,GPIB|USB|SOCKets|WEB|SERial}
:SYSTem:COMMunicate:ENABle?
{GPIB|USB|SOCKets|WEB|SERial}
Parameter 1
OFF | 0
Disables the selected interface.
ON | 1
Enables the selected interface.
Parameter 2
GPIB
Select GPIB
USB
Select USB
SOCKets
Select Sockets
WEB
Select the web server
SERial
Selected Serial (UART)
Return Parameter
Returns the status of the selected mode.
Example
SYST:COMM:ENAB 1,USB
Turns the USB interface on.
Query Example
SYST:COMM:ENAB? USB
1
Queries the USB state, returns 1 (USB is on).
:SYSTem:COMMunicate:GPIB[:SELF]:ADDR
ess
Set
Query
Description
Sets or queries the GPIB address. Note: the setting
will only be valid after the power has been cycled.
Syntax
Query Syntax
:SYSTem:COMMunicate:GPIB[:SELF]:ADDRess
:SYSTem:COMMunicate:GPIB[:SELF]:ADDRess?
Parameter/Return
0~30