PSU Programming Manual

106

Questionable Status Register Group

Overview

The Questionable Status Register Group
indicates if any protection modes or limits have
been tripped.

Condition

OV

0

PTR/NTP

Event

Enable

OC

1

Not Used

2

POW

3

OT

4

Not Used

5

Not Used

6

Not Used

7

VL

8

CL

9

Not Used

10

SD

11

PL

12

Not Used

13

Not Used

14

Not Used

15

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Questionable Status Register

&

&

&

&

&

&

&

&

&

&

&

&

&

&

&

&

Logical OR

To Status Byte Register

STATus:QUEStionable:CONDition? STATus:QUEStionable:EVENt?

STATus:QUEStionable:NTRansition

STATus:QUEStionable:NTRansition?

STATus:QUEStionable:PTRansition

STATus:QUEStionable:PTRansition?

STATus:QUEStionable:ENABle

STATus:QUEStionable:ENABle?

Bit Summary

Event

Bit #

Bit
Weight

OV (Over-Voltage)

Over voltage protection has been
tripped

0

1

OC (Over-Current)

Over current protection has been
tripped

1

2

POW (AC Power Off)

AC power switch is off

3

8