[:SOURce]:VOLTage[0]:SLEW:RISing

Set

Query

Description

Sets or queries the rising voltage slew rate. This is
only applicable for CV slew rate priority mode.

Syntax
Query Syntax

[:SOURce]:VOLTage[0]:SLEW:RISing
{(V)|MINimum|MAXimum}
[:SOURce]:VOLTage[0]:SLEW:RISing?

Parameter

0 ~ Vrated/100msec

MIN

Minimum rising voltage slew rate

MAX

Maximum rising voltage slew rate

Return parameter

Returns the slew rate in A/ms.

Example

SOUR:VOLT:SLEW:RIS MAX
Sets the rising voltage slew rate to its maximum.

[:SOURce]:VOLTage[0]:SLEW:FALLing

Set

Query

Description

Sets or queries the falling voltage slew rate. This is
only applicable for CV slew rate priority mode.

Syntax

[:SOURce]:VOLTage[0]:SLEW:FALLing
{(V)|MINimum|MAXimum}

Query Syntax

[:SOURce]:VOLTage[0]:SLEW:FALLing?

Parameter

0 ~ Vrated/100msec

MIN

Minimum voltage falling slew rate

MAX

Maximum voltage falling slew rate

Return parameter

Returns the voltage slew rate in A/ms

Example

SOUR:VOLT:SLEW:FALL MIN
Sets the falling voltage slew rate to its minimum.