Output commands, Output:delay:on, Output:external:logic – GW Instek PSU-Series Programming User Manual User Manual
Page 68
PSU Programming Manual
68
Output Commands
:OUTPut:DELay:ON ........................................................... 68
:OUTPut:EXTernal:LOGic ................................................. 68
:OUTPut:EXTernal[:STATe] ............................................... 69
:OUTPut:DELay:OFF .......................................................... 69
:OUTPut:MODE .................................................................. 69
:OUTPut:PON[:STATe] ....................................................... 70
:OUTPut[:STATe][:IMMediate] .......................................... 70
:OUTPut[:STATe]:TRIGgered ............................................ 71
:OUTPut:PROTection:CLEar ............................................. 71
:OUTPut:DELay:ON
Set
Query
Description
Sets the Delay Time in seconds for turning the
output on. The delay is set to 0.00 by default.
Syntax
Query Syntax
:OUTPut:DELay:ON {
:OUTPut:DELay:ON?
Parameter
0.00~99.99 seconds, where 0=no delay.
Return parameter "0.00"
Returns the delay on time in seconds until the
output is turned on.
:OUTPut:EXTernal:LOGic
Set
Query
Description
Sets the logic used to turn the output on or off
when using an external contact. This is the
equivalent to the F-94 (External Output Logic)
power on configuration settings.
Syntax
Return Syntax
:OUTPut:EXTernal:LOGic {LOW|HIGH}
:OUTPut:EXTernal:LOGic?
Parameter/
Return parameter
LOW
The output is turned on with a low
signal.
HIGH
The output is turned on with a high
signal.