beautypg.com

Sockets server configuration – GW Instek PSU-Series Programming User Manual User Manual

Page 49

background image

REMOTE CONTROL

49

Sockets Server Configuration

Configuration

This configuration example will configure the
PSU socket server.

The following configuration settings will
manually assign the PSU an IP address and
enable the socket server. The socket server port
number is fixed at 2268.

1. Connect an Ethernet cable from the

network to the rear panel Ethernet
port.

LAN

2. Press the Function key to enter the

Normal configuration settings.

Page 21

Set the following LAN settings:

F-36 = 1

Enable LAN

F-37 = 0

Disable DHCP

F-39 = 172

IP Address part 1 of 4

F-40 = 16

IP Address part 2 of 4

F-41 = 5

IP Address part 3 of 4

F-42 = 133

IP Address part 4 of 4

F-43 = 255

Subnet Mask part 1 of 4

F-44 = 255

Subnet Mask part 2 of 4

F-45 = 128

Subnet Mask part 3 of 4

F-46 = 0

Subnet Mask part 4 of 4

F-43 = 172

Gateway part 1 of 4

F-44 = 16

Gateway part 2 of 4

F-45 = 21

Gateway part 3 of 4

F-46 = 101

Gateway part 4 of 4

F-57 = 1

Enable Sockets