REMOTE CONTROL

79

Query Syntax

[:SOURce]:CURRent:PROTection:DELay?

Parameter

0.1~2.0 seconds, where 0=no delay

MAX

The maximum allowed delay time

MIN

The minimum allowed delay time

Return parameter

Returns the delay time in seconds

Example

SOUR:CURR:PROT:DEL MAX
Sets the current protection delay to the maximum.

[:SOURce]:CURRent:PROTection[:LEVel]

Set

Query

Description

Sets or queries the OCP (over-current protection)
level in amps.

Syntax

[:SOURce]:CURRent:PROTection[:LEVel] {(A)
|MINimum|MAXimum}

Query Syntax

[:SOURce]:CURRent:PROTection[:LEVel]?

Parameter

Current protection level.
Minimum: Depend on the unit type:
if Irated * 0.1 > 5A, then minimum = 5A,
else minimum = Irated * 0.1
Maximum: Irated * 1.1

MIN

Minimum current level.

MAX

Maximum current level.

Return parameter

Returns the current protection level.

Example

SOUR:CURR:PROT:LEV?
+5.000
Returns the minimum possible current level in amps.

[:SOURce]:CURRent:PROTection:STATe

Set

Query

Description

Turns OCP (over-current protection) on or off.

Syntax

[:SOURce]:CURRent:PROTection:STATe
{|OFF|ON}

Query Syntax

[:SOURce]:CURRent:PROTection:STATe?