beautypg.com

Configuration table – GW Instek PSU-Series Programming User Manual User Manual

Page 25

background image

GETTING STARTED

25

Configuration Table

Please use the configuration settings listed below when applying
the configuration settings.

Normal Function
Settings

Setting Setting Range

Output ON delay time

F-01

0.00s~99.99s

Output OFF delay time F-02

0.00s~99.99s

V-I mode slew rate select F-03

0 = CV high speed priority (CVHS)
1 = CC high speed priority (CCHS)
2 = CV slew rate priority (CVLS)
3 = CC slew rate priority (CVLS)

Rising voltage slew rate F-04

0.001~0.06V/msec (PSU 6-200)
0.001~0.125V/msec (PSU 12.5-120)
0.001~0.2V/msec (PSU 20-76)
0.001~0.4V/msec (PSU 40-38)
0.001~0.6V/msec (PSU 60-25)

Falling voltage slew rate F-05

0.001~0.06V/msec (PSU 6-200)
0.001~0.125V/msec (PSU 12.5-120)
0.001~0.2V/msec (PSU 20-76)
0.001~0.4V/msec (PSU 40-38)
0.001~0.6V/msec (PSU 60-25)

Rising current slew rate F-06

0.001~2A/msec (PSU 6-200)
0.001~1.2A/msec (PSU 12.5-120)
0.001~0.76A/msec (PSU 20-76)
0.001~0.38A/msec (PSU 40-38)
0.001~0.25A/msec (PSU 60-25)

Falling current slew rate F-07

0.001~2A/msec (PSU 6-200)
0.001~1.2A/msec (PSU 12.5-120)
0.001~0.76A/msec (PSU 20-76)
0.001~0.38A/msec (PSU 40-38)
0.001~0.25A/msec (PSU 60-25)