REMOTE CONTROL
81
[:SOURce]:CURRent:SLEW:FALLing
Set
Query
Description
Sets or queries the falling current slew rate. This is
only applicable for CC slew rate priority mode.
Syntax
[:SOURce]:CURRent:SLEW:FALLing
{
Query Syntax
[:SOURce]:CURRent:SLEW:FALLing?
Parameter
Per-Step is Rated Current divided by 100msec
MIN
Minimum falling current slew rate
MAX
Maximum falling current slew rate
Return Parameter
Returns the step current
Example
SOUR:CURR:SLEW:FALL MAX
Sets the falling current slew rate to the maximum.
[:SOURce]:MODE?
Set
Query
Description
Returns the status of the output mode (CC, CV,
Off) of the power supply.
The interface will return “CV’ if the supply is in
Constant Voltage Mode, “CC” if the supply is in
Constant Current Mode or “OFF” if the supply
output is off.
Query Syntax
[:SOURce]:MODE?
Return parameter
Returns the output state as a string, “CC”,
“CV”, “OFF”
Example
:SOUR:MODE?
>CC
The power supply is currently in CC mode.
[:SOURce]:RESistance[:LEVel][:IMMediate]
[:AMPLitude]
Set
Query
Description
Sets or queries the internal resistance in ohms.