REMOTE CONTROL

81

[:SOURce]:CURRent:SLEW:FALLing

Set

Query

Description

Sets or queries the falling current slew rate. This is
only applicable for CC slew rate priority mode.

Syntax

[:SOURce]:CURRent:SLEW:FALLing
{(A)|MINimum|MAXimum}

Query Syntax

[:SOURce]:CURRent:SLEW:FALLing?

Parameter

Per-Step is Rated Current divided by 100msec

MIN

Minimum falling current slew rate

MAX

Maximum falling current slew rate

Return Parameter

Returns the step current

Example

SOUR:CURR:SLEW:FALL MAX
Sets the falling current slew rate to the maximum.

[:SOURce]:MODE?

Set

Query

Description

Returns the status of the output mode (CC, CV,
Off) of the power supply.
The interface will return “CV’ if the supply is in
Constant Voltage Mode, “CC” if the supply is in
Constant Current Mode or “OFF” if the supply
output is off.

Query Syntax

[:SOURce]:MODE?

Return parameter

Returns the output state as a string, “CC”,
“CV”, “OFF”

Example

:SOUR:MODE?
>CC
The power supply is currently in CC mode.

[:SOURce]:RESistance[:LEVel][:IMMediate]
[:AMPLitude]

Set

Query

Description

Sets or queries the internal resistance in ohms.