If you are unable to remove the configuration because of a multi-slot trunk configuration, you must
first manually remove the multi-slot trunk configuration.

3.

When you have successfully deleted the mismatched stack unit, a re-election is triggered, and the
active controller learns the correct module configuration from the standby controller or from other
stack members. No reload is required.

Troubleshooting secure-setup

Secure-setup can be used to form linear and ring stack topologies. For information about the
procedure, refer to “Scenario 1 - Three-member traditional stack in a ring topology using secure-
setup”. During this procedure, if secure-setup does not detect all the units that should be detected,
perform the following checks:

Make sure that all the cables are properly connected

Make sure that all the relevant ports are in UP state

Make sure that all the units are running the same image

Make sure that you issue the stack enable command only on the unit that will serve as the active
controller

Make sure that stack disable is not configured on any prospective members

Make sure that the connection is sequential (refer to “Brocade traditional stacking terminology,
Sequential Connection”)

If secure-setup times out (this may happen due to inactivity), you will not be able to make any changes
in your configuration or stack topology until you restart the session by entering the stack secure-
setup
command.

The unit discovery process is triggered when secure-setup is initiated. However, if the stack unit is
placed in a topology where another unit in the stack is already running the discovery process, the
current discovery process is terminated. If this is the case, you will see a message similar to the
following.

"Topology discovery is already in progress originated from mac-address. Please try

later."

This means a discovery process is already active and was initiated from the unit with the mac-address
mentioned in the message. You will need to re-issue secure-setup.

If there is already an active discovery process, secure-setup may not discover all the intended units. If
this is the case, you will need to restart the secure-setup process.

Troubleshooting unit replacement issues

If you are unsuccessful in building a stack using the automatic setup process (refer to “Scenario 2 -
Three-member traditional stack in a ring topology using the automatic setup process”), or adding or
replacing a unit in a stack, consider the following issues:

Make sure that the number of units in your stack does not exceed the maximum of 8

Make sure that the replacement unit is a clean unit (does not contain a startup-config.txt file)

Make sure that the replacement unit running configuration does not contain “stack enable”

Make sure the replacement unit running configuration does not contain “stack disable”

Make sure that the configurations of the stack ports on the active controller match the physical
connections to the unit