Show hardware mac-entry – Brocade FastIron Ethernet Switch Stacking Configuration Guide User Manual
Page 153
Examples
The following is the sample output from the show chassis command executed on an ICX 6610 device.
Brocade# show chassis
The stack unit 1 chassis info:
Power supply 1 not present
Power supply 2 (AC - Regular) present, status ok
Model Number: 23-0000143-01
Serial Number: F00E
Firmware Ver: 0
Power supply 2 Fan Air Flow Direction: Back to Front
Fan 1 ok, speed (auto): [[1]]<->2
Fan 2 not present
Fan controlled temperature: 64.0 deg-C
Fan speed switching temperature thresholds:
Speed 1: NM<----->82 deg-C
Speed 2: 77<-----> 86 deg-C (shutdown)
Fan 1 Air Flow Direction:Back to Front
MAC 1 Temperature Readings:
Current temperature : 47.5 deg-C
CPU Temperature Readings:
Current temperature : 64.0 deg-C
sensor A Temperature Readings:
Current temperature : 45.5 deg-C
sensor B Temperature Readings:
Current temperature : 48.0 deg-C
sensor C Temperature Readings:
Current temperature : 35.5 deg-C
stacking card Temperature Readings:
Current temperature : 60.5 deg-C
Warning level.......: 70.0 deg-C
Shutdown level......: 86.0 deg-C
Boot Prom MAC : 0000.0034.289c
NOTE
The output of the show chassis command is different for ICX 6610 devices and FastIron SX devices.
History
Release
Command History
08.0.00a
This command was enhanced to display model number,
serial number, and firmware version number for power
supply units.
show hardware mac-entry
Displays the hardware MAC address entries with an option to display the MAC address and the VLAN
ID for a specific device.
Syntax
show hardware mac-entry [ device device_id mac_address vlan_id ]
Parameters
device
device_id
Specifies the hardware device number.
mac_address
Specifies a MAC address to be displayed.
vlan_id
show hardware mac-entry
FastIron Ethernet Switch Stacking Configuration Guide
151
53-1003090-02